E-CTF type |
E-CTF Laboratory Name |
E-CTF Address |
E-CTF Country |
Standards Covered |
Registration date |
Latest Revision date |
Report Ref. |
E-CTF-2 |
Siteco GmbH |
Georg-Simon-Ohm Strasse 50, 83301 Traunreut |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012-02
EN 60598-2-3:2003+A1:2011
EN 60598-2-4:2018
EN 60598-2-5:2015-11
EN 60598-2-13+A1+A2:2016
EN 60598-2-13:2006/A11:2021
EN 60598-2-18:1994 + A1:2012
EN IEC 60598-2-18:2022
EN 60598-2-19:1989+Corr.:2005
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
EN IEC 60598-2-2:2024
EN 62262:2002+A1:2021
|
2001-07-25 |
2024-11-04 |
40508-9501-0001/323586 (40036755) |
E-CTF-2 |
ERCO GmbH |
Brockhauser Weg 80-82, 58507 Luedenscheid |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses except the following:
4.4.4 (lampholder pressure test), 4.4.5 (voltage across lampholder),
4.20 (vibration test for rough service luminaires), 9.2.1 (IP5X), 9.2.2 (IP6X),13.3.1 (needle flame test), 13.4.1 (resistance to tracking)
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003+A1:2011
EN 60598-2-4:2018
EN 60598-2-5:2015
EN 60598-2-13:2006+A1:2012+A2:2016
EN 60598-2-18:1994+A1:2012
EN IEC 60598-2-18:2022
EN 60598-2-22:2014+A1:2020
EN IEC 660598-2-22:2022
EN 60570:2003+A1:2018+A2:2020
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
All clauses except a.c. supplied LED modules
EN 60838-1:2017+A1:2017
EN 60838-1:2017+A1:2017+A2:2021+A11:2021
All clauses except 17.4, 17.5, 18.1, 18.2
EN IEC 62471-7:2023
|
2006-10-10 |
2024-02-15 |
411100-9501-0001/316321
(40037505) |
E-CTF-2 |
BEGA Gantenbrink-Leuchten KG |
Hennenbusch, 58708 Menden |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses, except cl. 9.2.9
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003+A1:2011
EN 60598-2-4: 2018
EN 60598-2-5:2015
EN 60598-2-13:2006+A1:2012+A2:2016
EN 60598-2-13:2006/A11:2021
EN 60598-2-18:1994+A1:2012
EN 60598-2-20:2015
EN 60598-2-22: 2014
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
EN 62031:2008+A1:2013+A2:2015
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
EN IEC 60598-2-2:2024
All clauses
EN IEC 60598-2-20: 2024
EN IEC 60598-2-20/A11: 2024
All clauses
EN 62262:2002+A1:2021
All clauses
EN IEC 62471-7:2023
All clauses |
2016-01-09 |
2024-01-09 |
428400-9501-0001/323252
(40039235) |
E-CTF-2 |
REGIOLUX GmbH |
Hellinger Strasse 3, 97486 Königsberg |
Germany |
EN 60598-1:2015 + A1:2018
all clauses except 9.2 / 9.3 / 10 / 13
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
all clauses except 9.2 / 9.3 / 10 / 13
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-4:2018
all clauses
EN 60598-2-22:2014+A1:2020
all clauses except 22.17
EN IEC 60598-2-22:2022
EN 60598-2-2:2012
all clauses
EN 60598-2-24:2013
all clauses
EN 60598-2-22:2014
all clauses except 22.17
|
2006-12-08 |
2024-06-19 |
428500-9501-0001/320070
(40036756) |
E-CTF-1 |
Ansorg GmbH |
Pilgerstrasse 11, 45473 Mülheim/Ruhr |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses except 9, 10, 12.3, 13.2, 13.3.1, 13.4
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-4: 2018
All clauses
EN 60598-1:2015+A1:2018
all clauses except
9, 10, 12.3, 13.2,
13.3.1, 13.4
EN 60598-2-22: 2014
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
all clauses except
22.13.1, 22.14, 22.16, 22.17, 22.18, 22.19, 22.21
EN IEC 60598-2-2:2024
All clauses
|
2004-07-21 |
2024-06-28 |
808800-9501-0001/319629
(40038002) |
E-CTF-2 |
BJB GmbH & Co. KG |
Werler Strasse 1, 59755 Arnsberg |
Germany |
EN IEC 60238:2018+A1:2018
EN IEC 60238:2018+A1:2018+A2:2021
EN 60400:2017
EN 60400:2017+A1:2021
EN 61184:2017
EN 60838-1:2017
N 60838-1/A1:2017
EN 60838-1:2017+A1:2017+A2:2021+A11:2021
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
All clauses, except clause 21
(22 PHOTOBIOLOGICAL SAFETY) |
2008-07-07 |
2023-12-07 |
14600- 9501-0001/312228
(40038937) |
E-CTF-3 |
Inventronics GmbH |
Parkring 31-33,
85748 Garching |
Germany |
EN 61347-1:2015
EN 61347-1:2015+A1:2021
EN 61347-2-2:2012
EN 61047:2004
EN 61347-2-3:2011+A1:2017
EN 60929:2011+A1:2016
EN 61347-2-11:2011+A1:2019
EN 61347-2-12:2005+A1:2010
EN 61347-2-13:2014+A1:2017
EN 62384:2006+A1:2009
EN IEC 62384:2020
EN 62031:2008+A1:2013+A2:2015
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
|
2013-11-04 |
2023-03-09 |
5017767-9501-0001/300288
(40038719) |
E-CTF-2 |
PIT GmbH |
Am Sseerain Nr. 3, 35232 Dauthphetal-Buchenau |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-5:2015
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
valid for all listed standards:
accepted clauses: 3, 12 (except 12.3) |
2006-10-12 |
2023-09-28 |
527600-9501-0001/309281
(40038930) |
E-CTF-2 |
RIDI Leuchten GmbH |
Hauptstraße
31-33,
72417 Jungingen |
Germany |
EN 60598-1:2015+A1:2018
(All clauses, except: 9, 10, 13.2, 13.3.1, 13.4, 15)
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses, except: clause 1.13 (9), clause 1.14 (10), clause 1.15 (13.2,
13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
All clauses, except: clause 1.13 (9), clause 1.14 (10), clause 1.15 (13.2,
13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-2:2012
EN IEC 60598-2-2:2024
All clauses, except: clause 2.14 (9), clause 2.15 (10), clause 2.16 (13.2, 13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-3:2003+A1:2011
All clauses, except: clause 3.13 (9), clause 3.14 (10), clause 3.15 (13.2,
13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-4: 2018
All clauses, except: clause 4.14 (9),
clause 4.15 (10), clause 4.16 (13.2, 13.3.1, 13.4) (numbers in brackets refer
to the relevant clauses of 60598-1)
EN 60598-2-5:2015
All clauses, except: clause 5.13 (9),clause 5.14 (10), clause 5.15
(13.2,13.3.1, 13.4)(numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
All clauses, except: clause 22.14 (9), clause 22.15 (10), clause 22.16 (13.2,
13.3.1, 13.4), clause 22.17, clause 22.18, clause 22.19, clause 22.20,
clause 22.21 (numbers in brackets refer to the relevant clauses of 60598-1)
EN 60598-2-24:2013
All clauses, except: clause 24.14 (9), clause 24.15 (10), clause 24.16 (13.2,
13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
All clauses, except: clause 11, clause 12
EN 60570:2003+A1:2018
EN 60570:2003+A1:2018+A2:2020 IEC 60570:2003
All clauses, except: clause.14 (9), clause.15 (10), clause.17 (13.2, 13.3.1, 13.4) (numbers in brackets refer to the relevant clauses of 60598-1)
|
2016-02-24 |
2024-08-05 |
565600-9501-0001/319801
(40043767) |
E-CTF-2 |
A. u. K. Müller gmbH & Co. KG |
Dresdener Straße 162, 40595 Düsseldorf |
Germany |
EN 60730-1:2016+A1:2019
EN 60730-1:2016/A2:2022
Accepted clauses 12 – 17,
18, 27
EN IEC 60730-2-8:2020
EN IEC 60730-2-8:2020+A1:2021
Accepted clauses 12 – 17,
18, 27 for 18 Appendix BB;
Appendix CC |
2016-08-29 |
2024-07-18 |
513100-9501-0006/320846
(40044847) |
E-CTF-2 |
NORKA Norddeutsche Kunststoff- und
Elektrogesellschaft Stäcker mbH & Co. KG |
Lange Straße 1, 27313 Dörverden-Hülsen |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003+A1:2011
EN 60598-2-4:2018
EN 60598-2-5:2015
EN 60598-2-13:2006+A1:2012+A2:2016
EN 60598-2-18:1994+A1:2012
EN 60598-2-22:2014+A1:2020
except of self-contained luminaires
EN 60598-2-22: 2014
except of self-contained luminaires
EN 60598-2-22:2014+A1:2020
except of self-contained luminaires
EN 60598-2-24:2013
|
2007-09-30 |
2024-01-16 |
2486300-9501-0001/312670
(40036260) |
E-CTF-3 |
Inventronics S.R.L. |
Via Castagnole 65a, 31100 Treviso |
Italy |
EN 62717:2017/A2:2019
EN IEC 62722-2-1:2023
Except tests with the gonio photometer |
2016-03-08 |
2023-11-09 |
4343100-9501-0001/309777
(40043907) |
E-CTF-2 |
RZB Rudolf Zimmermann Bamberg GmbH |
Rheinstraße 16, 96052 Bamberg |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses except 9.2.1, 9.2.2
EN 60598-2-1:1989
All clauses
EN IEC 60598-2-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses except 9.2.1, 9.2.2
EN 60598-2-2:2012
DIN EN 60598-2-2(VDE 0711-2-2):2012-10
EN 60598-2-2:2012
IEC 60598-2-2:2011
DIN EN 60598-2-2(VDE 0711-2-2):2012-10
EN 60598-2-2:2012
IEC 60598-2-2:2011
DIN EN 60598-2-2(VDE 0711-2-2):2012-10
EN 60598-2-2:2012
IEC 60598-2-2:2011
All clauses
Luminaires – Part 2-2:
Particular requirements
– Recessed luminaires
Luminaires – Part 2-2:
Particular requirements
– Recessed luminaires
Luminaires – Part 2-2:
Particular requirements
– Recessed luminaires
EN IEC 60598-2-2:2024
All clauses
EN 60598-2-3:2003+A1:2011
EN 60598-2-4:2018
EN 60598-2-5:2015
EN 60598-2-8:2013
EN 60598-2-10:2003
All clauses
EN 60598-2-11:2013+A1:2022
EN 60598-2-13:2006+A1:2012+A2:2016
EN 60598-2-13:2006/A11:2021
All clauses
EN IEC 60598-2-17:2018
EN 60598-2-18:1994+A1:2012
EN IEC 60598-2-18:2022
EN 60598-2-19:1989
EN 60598-2-19/A2:1998
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
EN 60598-2-25:1994+A1:2004
|
2009-11-25 |
2024-08-09 |
28100-9501-0001/320113
(40038045) |
E-CTF-2 |
Performance in Lighting GmbH |
Stapelner Straße 1+3, 38644 Goslar |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All Clauses, except 9.2.1 - 9.2.9, 9.3, 13.3, 13.4
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-4: 2018
EN 60598-2-22: 2014
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
All Clauses
|
2009-11-23 |
2024-04-24 |
1991000-9501-0001/317935
(40039365) |
E-CTF-2 |
Vossloh-Schwabe Deutschland GmbH |
Stuttgarter Straße 61/1
73614 Schorndorf |
Germany |
EN 61347-1:2015
EN 61347-1:2015 + A1:2021
EN 61347-1:2008 + A1 + A2:2013
EN 61347-2-2:2012
EN 61047:2004
EN 61347-2-1:2001+A1:2006+A2:2014-02
EN 61347-2-3:2011+A1:2017
EN 60929:2011+A1:2016
EN 61347-2-7:2012+A1:2019+A2:2022
EN 61347-2-8:2001+A1:2006
EN 60921:2004+A1:2006
EN 61347-2-9:2013
EN 60923:2005+A1:2006
EN 61347-2-11:2001+A1:2019
EN 61347-2-12:2005+A1:2010
EN 61347-2-13:2014+A1:2017
EN IEC 62384:2020
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
EN 60570:2003+A1:2018
EN 60570:2003+A1:2018+A2:2020
EN 60838-1:2017
EN 60838-1/A1:2017
EN 60838-1:2017+A1:2017+A2:2021+A11:2021
EN 60400:2017
EN 60400:2017+A1:2021
EN IEC 62471-7:2023
|
2019-12-19 |
2024-05-28 |
2378800-9501-0005/322594
(40045571) |
E-CTF-2 |
TRILUX GmbH & Co. KG |
Heidestraße 4, 59759 Arnsberg |
Germany |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
All clauses except clause 9.2.8, 9.2.9
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003+A1:2011
EN 60598-2-4: 2018
EN 60598-2-5:2015
EN 60598-2-13:2006+A1:2012+A2:2016
EN 60598-2-13:2006/A11:2021
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
EN 60598-2-25:1994+A1:2004 |
2014-02-10 |
2023-12-12 |
299800-9501-0001/309204
(40039373) |
E-CTF-3 |
Inventronics S.R.L. |
Via Castagnole No. 65a
31100 TREVISO TV |
Italy |
EN 60598-1:2015+A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
All clauses except of self-contained luminaires
EN 62031:2008+A1:2013+A2:2015
EN IEC 62031:2020
EN IEC 62031:2020/A11:2021
EN 61347-1:2015
EN 61347-1:2015+A1:2021
EN 61347-2-2:2012
EN 61347-2-11:2001+A1:2019
EN 61347-2-13:2014+A1:2017
EN 62384:2006+A1:2009
EN IEC 62384:2020 |
2009-08-18 |
2023-11-09 |
4343100-9501-0001/309773
(40037620) |
E-CTF-2 |
WE-EF LEUCHTEN GmbH |
Toepinger Straße 16, 29646 Bispingen |
Germany |
EN 60598-1:2015+A1:2018
All clauses, except 4.13, 4.24, 9.3 and 10
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
All clauses, except 4.13, 4.24, 9.3 and 10
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003+A1:2011
EN 60598-2-5:2015
EN 60598-2-13:2006+A1:2012+A2:2016
All clauses, except 13.6.1 and 13.6.2
EN 60598-2-18:1994+A1:2012
EN IEC 60598-2-18:2022
|
2016-02-16 |
2023-12-11 |
823100-9501-0001/312544
(40043766) |
E-CTF-2 |
Adolf Schuch GmbH |
Lichttechnische Spezialfabrik
Mainzer Str. 172, 67547 Worms |
Germany |
EN 60598-1:2015 +A1:2018
EN IEC 60598-1:2021
EN IEC 60598-1:2021/A11:2022
EN 60598-2-1:1989
EN IEC 60598-2-1:2021
EN 60598-2-2:2012
EN 60598-2-3:2003 +A1:2011
EN 60598-2-5: 2015
EN 60598-2-22:2014
EN 60598-2-22:2014+A1:2020
EN IEC 60598-2-22:2022
EN 60598-2-24:2013
all clauses |
2014-05-12 |
2024-06-20 |
39600-9501-0001/319807
(40039893) |
E-CTF-3 |
TRILUX GmbH & Co. KG |
Heidestraße 4, 59759 Arnsberg |
Germany |
EN 62717:2017+A2:2019
EN 62717:2017
PD EPRS 001:2018-05
EN 62722-1:2016
PD EPRS 002:2018-05
EN 62722-2-1:2016
PD EPRS 003:2018-05 |
2016-12-19 |
2023-12-14 |
299800-9501-0001/309282
(40045576) |
E-CTF-2 |
WALTHER-WERKE
Ferdinand Walther GmbH |
Ramsener Str. 6,
67304 Eisenberg |
Germany |
EN 60309-1:1999+A1:2007+A2:2012
EN 60309-2:1999+A1:2007+A2:2012
Accepted clauses 7; 8; 9; 12; 13; 14; 15; 16; 17;
18 (without Dust); 19; 22; 23; 24; 25; 26;
27 (without 27.5); 28
|
2018-07-27 |
2023-03-28 |
247000-9501-0001/299901
(40048560) |
E-CTF-2 |
KEDU Electric Co.,Ltd. |
Building 1, No.88, Songqiao street,
310018 QIANTANG DISTRICT, HANGZHOU |
China |
EN IEC 60947-1:2021
(No tests)
EN 60947-2:2017+A1:2020
(All clauses except EMC)
EN IEC 60947-3:2021
(All clauses except EMC)
EN IEC 60947-4-1:2019
(All clauses except EMC)
EN 60947-5-1:2017
(All clauses except EMC)
EN 60898-1:2019
EN 60898-2:2021
EN 61008-1:2012+A1:2014+
A1:2014/AC:2016+A2:2014+
A11:2015+A12:2017
(All clauses except EMC)
EN 61008-2-1:1994+A11:1998+Corr. 1999
(All clauses except EMC)
EN 61009-1:2012+A1:2014+A2:2014+
A11:2015 + A12:2016+A13:2021
(All clauses except EMC)
EN 61009-1:2012+A1:2014+
A2:2014+A11:2015+A12:2016
(All clauses except EMC)
EN 62423:2012+A11:2021
(All clauses except EMC)
EN IEC 61058-1:2018
EN 61058-1-1:2016 |
2022-09-28 |
2023-10-27 |
5029586-9501-0001/310302
(40052023) |
E-CTF-2 |
Inventronics Guangzhou Technology Ltd |
Shenzhen Branch
Unit 201, 2F, Blk. B, Emerging Ind. Park No.3151, Shahe West Road Xili, Nanshan District, 518055 SHENZHEN |
China |
EN 61347-1:2015 + A1:2021
All clauses except clause
18.2, 18.5 and Annex N
EN 61347-2-13:2014+A1:2017
All clauses
EN IEC 62384:2020
All clauses |
2023-06-23 |
2024-08-14 |
5030378-9501-0001/322616