Certification Body Name:
IMQ - ISTITUTO ITALIANO DEL MARCHIO DI QUALITA' S.p.A.

Back to members

 

CB Acronym: IMQ ID #: 03
Contact person: Dr. Mauro Casari
Address 1: Via Quintiliano 43
City: Milano Postal code: I - 20138
State / Province: IT Country: Italy
Address 2:
Email address: mauro.casari@imq.it Url: http://www.imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:  
Deadline for the next Re-assessment: 2024-11-03
Comments:

Aditionnal contacts informations

Mr. Matteo Raismondi

Email address: matteo.raimondi@imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:
 

 

 

ENEC
CB IMQ - Product Category
BATT
CAP
CONT
HOR
HOUS
INST
ITAV
LITE
MISC
POW
PROT
SAFE
TOOL
Laboratory Name Acronyme Country City
Guangdong Testing Institute of Product Quality Supervision GQI China Guangzhou
Istituto Italiano del Marchio di Qualita S.p.A. IMQ Italy Milano
IMQ IBÉRICA, S.L.U. IMQ Ibérica Spain Picanya
ZANELLI S.r.l. ZANELLI S.r.l. Italy Vailate (CR)
E-CTF type E-CTF Laboratory Name E-CTF Address E-CTF Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF-2 3F FILIPPI S.p.A. (PROVE E COLLAUDI) Via del Savena, 28 IT-40065 Pianoro Bologna (BO) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 8.2.7, 9.2.10, 9.2.11, 9.3.1, 12.5.1e) Annex C Fig. C3, 12.7.2, 13.2.1, 13.3.1, 13.3.2, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.5, Annex C, 22.18, 22.20 [Type of operation: centrally supplied emergency luminaires only]); EN IEC 60598-2-22:2022 (All clauses except 22.17.5, Annex C, 22.18, 22.20 [Type of operation: centrally supplied emergency luminaires only]); EN 60598-2-24:2013; EN IEC 62031:2020 + A11:2021 (All clauses except 10, 12.1, 16, 17, 18, 20, 21, Annex D) [EMC] EN IEC 55015:2019 + A11:2020 (All clauses except: - Insertion loss measurement - Radiated disturbance measurements in semi-anechoic chamber (frequency range 30 MHz to 300 MHz covered by independent method – CDNE-method) (# 9) - Conical metal housing for single capped lamps. Electrical power supply interface disturbance measurements.); EN IEC 61547:2023 (All clauses except: - Continuous radiated radio frequency disturbance (# 5.3) - Power frequency magnetic fields (# 5.4) - Continuous radio frequency disturbance (# 5.6)); EN IEC 61000-3-2:2019 + A1:2021; EN 61000-3-3:2013 + A1:2019 + A2:2021 2007-03-06 2024-03-06 IMQ-078/E-CTF2 Issue No: 3
E-CTF-2 A.A.G. STUCCHI S.r.l. unico socio [Prod. Cat.: INST - LITE] Via IV Novembre, 30/32 IT-23854 Olginate Lecco (LC) Italy [INST] EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004 (All clauses except 12.3); EN 60998-2-2:2004 (All clauses except 12.3); EN 61984:2009 (All clauses except 7.3.7, 7.3.9, 7.3.10, 7.3.13, 7.3.14, 7.4.2) [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3); EN 60400:2017 + A1:2021 (All clauses except 10.2 (only for soldering lugs)); EN 60838-1:2016 + A1:2017 + A11:2021 + A2:2021 (All clauses except 8.2 (only for soldering lugs)); EN 60570:2003 + A1:2017 + A2:2020 (All clauses except 14) 2006-11-23 2023-12-14 IMQ-071/E-CTF2 Issue No: 1
E-CTF-2 AB PLAST S.r.l. Via Fura, 38/A IT - 25125 Brescia (BS) Italy [INST] EN 60669-1:2018 (All clauses except 15.2.2 (for degrees of protection higher than IPX4), 15.2.3 (for degree of protection higher than IPX6)) 2021-11-25 2022-11-25 IMQ-402/E-CTF2 Issue No: 1
E-CTF-2 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: EMC] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [EMC] EN 61000-4-2:2009; EN 61000-4-4:2012; EN 61000-4-5:2014 + A1:2017; EN 61000-4-6:2014; EN 61000-4-8:2010 (Accepted clauses of only continuous field up to 30 A/m); EN 61000-4-9:2016; EN IEC 61000-4-11:2020 + AC:2020 (All clauses (single-phase systems only)); EN 61000-4-16:2016 (All clauses except short duration disturbances); EN 61000-4-19:2014 (All clauses except Rectangular Modulation); EN 61000-4-20:2010; EN 55011:2016 + A1:2017 + A11:2020 (Accepted sub-slause 8.2 (Conducted Emissions)); EN 55014-1:2017 + A11:2020 (All clauses except 5.3.2, 5.3.3, 5.4.2); EN IEC 55015:2019 + A11:2020; EN 55032:2015 + A1:2020 + A11: 2020 (Accepted Annex A.3 (Conducted Emissions)); EN IEC 61000-6-1:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN IEC 61000-6-2:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN 61000-6-3:2007 + A1:2011 (All clauses except tests belonging to IEC 61000-3 series); EN IEC 61000-6-4:2019; EN 61326-1:2013 (All clauses except Radiated emission measurement and Electromagnetic field); EN IEC 61326-1:2021 (All clauses except Radiated emission measurement and Electromagnetic field); EN 61557-12:2008 (All clauses except radiated emission measurement and Electromagnetic field); EN IEC 61557-12:2022 (All clauses except radiated emission measurement and Electromagnetic field); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (All clauses except Ref. T 2.5 of Tab. 2 and radiated emission measurements); EN IEC 61523:2023 + A11:2023 (All clauses except Radiated high-frequency phenomena and Radiated emission measurements); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 8.4.1 (except 8.4.1.2.3, 8.4.1.2.7)); EN 60947-2:2017 (Accepted Annex J (except J.2.3, J.3.3)); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61008-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62423:2012 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62606:2013 + A1:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (except 26.1.5, 26.1.7)); EN IEC 60669-2-1:2022 + A11:2022 (Accepted clause 26 (except 26.1.5, 26.1.7)); EN 60669-2-5:2016 (Accepted clause 26 (except 26.2.6, 26.2.8, 26.3.1, 26.3.4)); EN 50491-5-1:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50491-5-2:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50130-4:2011 + A1:2014; ETSI EN 301 489-1 V2.2.3 (All clauses except Radiated emission measurement and Electromagnetic field); ETSI EN 301 489-3 V2.1.1 (All clauses except radiated emission measurement and Electromagnetic field); ETSI EN 301 489-17 V3.2.4 (All clauses except radiated emission measurement and Electromagnetic field); CLC/TR 50579:2012; EN 50470-1:2006 + A1:2018 (Accepted clauses 6.3.2, 6.3.3, 6.3.4, 7.3, 7.4.4, 7.4.5, 7.4.7, 7.4.8, 7.4.9, 7.4.13 (limited to conducted tests)); EN 50470-3:2006 + A1:2018 (Accepted clauses 8.1, 8.4, 8.7.2, 8.7.3, 8.7.4, 8.7.5.2, 8.7.5.3, 8.7.5.4, 8.7.6, 8.7.7.2, 8.7.7.3, 8.7.7.4, 8.7.7.5, 9.7.7.7, 8.7.7.8, 8.7.7.9, 8.7.9.3, 8.7.9.4, 8.7.10, 9, 10)); EN 62059-32-1:2012; EN IEC 62052-11:2021 + A11:2022 (Accepted clause 9 (except 9.3.2, 9.3.4, 9.3.5, 9.3.8 - Triangular Modulation, 9.3.12, 9.3.13, 9.3.14 - Radiated Emission)); EN 63024:2018 (Accepted clause 22 (except Radiated Emission measurement and Electromagnetic field)) 2017-06-09 2023-06-06 IMQ-308/E-CTF2 Issue No: 1
E-CTF-3 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: INST - PROT (Protection Devices)] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 9.4.2.3); EN IEC 60947-1:2021 (All clauses except 9.4.2.3); EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2016 + A1:2020 (All clauses except Annex J.2.3); EN 60947-3:2009 + A1:2012; EN IEC 60947-3:2021 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61008-2-1:1994 + A11:1998 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61009-2-1:1994 + A11:1998 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 62423:2012 + A11:2021 + A12:2022 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 62606:2013 + A1:2017 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 60269-1:2007 + A1:2009 + A2:2014; HD 60269-2:2013; HD 60269-3:2010 + A1:2013 2003-06-19 2023-07-19 IMQ-019/E-CTF3 Issue No: 1
E-CTF-3 ARISTON S.p.A. (Laboratorio Prove) Via Pascoli, 1 IT-60044 Fabriano Ancona (AN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-2-21:2003 + A1:2005 + A2:2008; EN 60335-2-21:2021 + A1:2021; EN 60335-2-35:2002 + A1:2007 + A2:2011; EN 60335-2-35:2016 + A1:2019 + A2:2021 (All clauses except Annex R); EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + A2:2009 + A13:2012 1991-04-08 2023-11-15 IMQ-012/E-CTF3 Issue No: 2
E-CTF-2 BAXI S.p.A. (R&D LABORATORY) Via Trozzetti, 20 IT-36061 Bassano del Grappa Vicenza (VI) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A14:2019 + A1:2019 + A2:2019 + A15:2021 (All clauses except 19.11.4 (EMP), 29, 30.1, 30.2); EN 60335-2-102:2016; EN 60529:1991 + A1:2000 + A2:2013 (All clauses (only for protection degrees IPX4, IPX5, IPXXD)) 1997-07-18 2023-05-18 IMQ-002/E-CTF2 Issue No: 1
E-CTF-2 BEGHELLI S.p.A. (Laboratorio Certificazione Beghelli) Via Mozzeghine, 13/15 IT-40053 Valsamoggia - Località Monteveglio Bologna (BO) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 5.2.10, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 10.3.1, 12.5.1e) Annex C Fig. C3, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-8:2013 (All clauses except 8.11.4.1, 8.16.1); EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 60598-2-24:2013; EN 61347-1:2015 + A1:2021 (All clauses except 14.6, 17, 18.2, 18.4, 18.5, 19, Annex B (B.9.5)); EN 61347-2-7:2012 + A1:2019 + A2:2022 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 61347-2-11:2001 + A1:2019; EN 61347-2-13:2014 + A1:2017; EN IEC 62031:2020 + A11:2021 (All clauses except 21, Annex D) 2005-10-10 2024-05-22 IMQ-058/E-CTF2 Issue No: 3
E-CTF-2 BOCCHIOTTI S.p.A. Via Pian Masino, 109 IT-16011 Arenzano Genova (GE) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A11:2011; EN 50085-2-2:2008 (All clauses except 14.101); EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021; EN 61386-22:2004 + A11:2010; EN IEC 61386-22:2021 + A11:2021; EN 61386-23:2004 + A11:2010; EN IEC 61386-23:2021 + A11:2021; EN 60670-1:2005 + A1:2013 (All clauses except 19); EN IEC 60670-1:2021 + A11:2021 (All clauses except 19); EN 60670-22:2006; EN 60670-23:2008; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.12, 9.13) 2005-10-10 2023-04-17 IMQ-056/E-CTF2 Issue No: 1
E-CTF-2 BONFERRARO S.p.A. Via Oberdan, 57 IT-37060 Bonferraro di Sorgà Verona (VR) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 19.11.4 (EMP), Annex R; Annex T); EN 60335-2-5:2015 + A11:2019 + A1:2020 [MEAS] EN 61010-1:2010 + A1:2019 (All clauses except 11.6, 12.2.1, 12.2.2, 12.3, 12.4, 12.5.2, 12.6, 13.2.3, 14.8, Annex H); EN 61010-2-040:2015 (All clauses except 7.106, 12.3, 13.1, 13.101); EN IEC 61010-2-040:2021 (All clauses except 7.106, 12.3, 13.1, 13.101) 2001-05-08 2022-11-21 IMQ-004/E-CTF2 Issue No: 1
E-CTF-3 BTICINO S.p.A. (SALA PROVE BTICINO) Viale L. Borri, 231 IT-21100 Varese Varese (VA) Italy [INST] EN 50085-1:2005; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61242:1997 + A1:2008; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 50250:2002 (All clauses except 8); EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010; EN 50428:2005 + A1:2007 + A2:2009 (All clauses except 26.2.3, 26.2.4); EN 60669-2-2:2006; EN 60669-2-3:2006; EN 60669-2-4:2005; EN 60669-2-5:2016 (All clauses except 26.2.3, 26.2.4); EN 62080:2009 + A2:2015; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN IEC 60670-1:2021 + A11:2021; EN 60670-22:2008; EN 60670-24:2013; EN 61386-1:2008 + A1:2019 (All clauses except 13.1.3.2); EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021 (All clauses except 13.1.3.2); EN 61386-22:2004 + A11:2010; EN IEC 61386-22:2021 + A11:2021 (All clauses except 13.1.3.2); EN 61386-23:2004 + A11:2010; EN IEC 61386-23:2021 + A11:2021 (All clauses except 13.1.3.2); EN 62444:2013 [POW] EN 62019:1999 + A1:2003 + A11:2005 + A12:2014; 2004; EN 60439-1:1999 + A1:2004; EN 61439-1:2011; EN 61439-2:2011; EN 60947-1:2007 + A1:2011 + A2:2014; EN IEC 60947-1:2021; EN 60947-2:2006 + A1:2009 + A2:2013; EN 60947-2:2017; EN 60947-3:2009 + A1:2012 + A2:2015; EN IEC 60947-3:2021; EN 60947-5-1:2004 + A1:2009 [CONT] EN 60934:2001 + A1:2007 + A2:2013 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014; EN 61008-2-1:1994 + A11:1998; EN 61009-1:2012 + A1:2014 + A2:2014; EN 61009-2-1:1994 + A11:1998; EN 62423:2012; EN 50557:2011; EN 61643-11:2012 + A11:2018 [EMC] EN 61543:1995 + A11:2003 + A12:2005 + A2:2006 2006-03-16 2023-05-04 IMQ-060/E-CTF3 Issue No: 2
E-CTF-2 BTICINO S.p.A. (SALA PROVE BTICINO) [Prod. Cat.: INST] Strada della Guasca, 201 IT-15122 Spinetta Marengo Alessandria (AL) Italy [INST] EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010 (Accepted clause 13.1.3.2); EN IEC 61386-21:2021 + A11:2021 (Accepted clause 13.1.3.2); EN IEC 61386-22:2021 + A11:2021 (Accepted clause 13.1.3.2); EN IEC 61386-23:2021 + A11:2021 (Accepted clause 13.1.3.2); EN 61537:2007 2007-12-31 2023-11-16 IMQ-206/E-CTF2 Issue No: 1
E-CTF-3 CANDY HOOVER GROUP S.r.l. (EMC/LVD Washing Lab) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 19.11.4.2); EN 60335-2-5:2015 + A11:2019 + A1:2020; EN 60335-2-7:2010 + A1:2013 + A11:2013 + A2:2019; EN IEC 60335-2-7:2023 + A11:2023; EN 60335-2-11:2010 + A11:2012 + A1:2015 + A2:2018 (All clauses except Annex BB); EN IEC 60335-2-11:2022 + A11:2022 (All clauses except Annex BB); EN 61770:2009 + A11:2018 + A1:2019 + A12:2022 (All clauses except: §8 – Dynamic backflow preventers §9 – Hose-sets) [EMC] EN 62233:2008 2005-01-01 2023-10-18 IMQ-005/E-CTF3 Issue No: 2
E-CTF-2 Cariboni Group S.p.A. Via della Tecnica, 19 IT-23875 Osnago Lecco (LC) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.13.6, 4.14.1, 4.14.2, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60598-2-24:2013; EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2g), 7, 10, 12.1, 16, 17, 18, 20, 21, Annex A, Annex D); EN 62262:2002 All clauses [Test Eha (pendulum hammer), Test Ehb (Spring hammer) and Test Ehc (Vertical hammer) according to IEC/EN 60068-2-75:2014)] 2018-04-09 2024-05-22 IMQ-045/E-CTF2 Issue No: 3
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio CAFFE’) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021; EN 60335-2-75:2004 + A11:2006 + A1:2005 + A2:2008 + A12:2010 (All clauses except 15.1.1, Annex AA); EN IEC 60335-2-75:2023 + A11:2023 + A1:2023 + A2:2023 (All clauses except 15.1.1, Annex AA) 2006-02-08 2024-05-21 IMQ-066/E-CTF2 Issue No: 2
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COMFORT) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-30:2009 + A11:2012 + A1:2020 + A12:2020 + A13:2022 + A2:2022; EN 60335-2-43:2003 + A1:2006 + A2:2008; EN IEC 60335-2-43:2020 + A11:2020; EN 60335-2-65:2003 + A1:2008 + A11:2012 + A12:2022 + A2:2022 (All clauses except 32, Annex AA); EN 60335-2-80:2003 + A1:2004 + A2:2009 2005-07-05 2024-05-23 IMQ-029/E-CTF2 Issue No: 2
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COTTURA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-9:2003 + A1:2004 + A2:2006 + A12:2007 + A13:2010; EN IEC 60335-2-9:2023 + A11:2023; EN 60335-2-13:2010 + A11:2012 + A1:2019; EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021 2006-02-08 2023-11-14 IMQ-067/E-CTF2 Issue No: 1
E-CTF-2 DE’ LONGHI APPLIANCES s.r.l. (Laboratorio STIRO & PULIZIA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-2:2010 + A11:2012 + A1:2013 (All clauses except 21); EN 60335-2-3:2016 + A1:2020; EN 60335-2-85:2003 + A1:2008 + A11:2018 + A2:2020 2006-07-11 2024-05-20 IMQ-096/E-CTF2 Issue No: 3
E-CTF-2 DISANO ILLUMINAZIONE S.p.A. (Laboratorio Misure e Prove) Via Scaldasole, 8 IT-27020 Dorno Pavia (PV) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.2.1, 13.6.2.2); EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.5 Annex C); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 7, 10, 16, 17, 18, 20, 21, Annex A, Annex D); EN 62262:2002 - IEC TR 62696:2011 (All clauses [Test Ehb (Spring hammer) and Test Ehc (Vertical hammer) according to IEC/EN 60068-2-75:2014)] [EMC] EN 61547:2009 (All clauses except 5.2, 5.3, 5.4, 5.6); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55015:2013 + A1:2015 (All clauses except 7, 8.1.2, 8.1.3, 9.2) 2005-08-02 2023-07-28 IMQ-037/E-CTF2 Issue No: 1
E-CTF-2 DUCATI ENERGIA S.p.A. Via M.E. Lepido, 182 IT-40132 Bologna Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:2014 (Accepted clauses 17, 18, 19) 2005-11-22 2022-11-07 IMQ-080/E-CTF2 Issue No: 1
E-CTF-2 ELETTROTECNICA ROLD S.r.l. Via della Merlata, 1 IT-20014 Nerviano Milano (MI) Italy [CONT] EN 60730-1:2011 (All clauses except 23, 26, Annex H); EN 60730-1:2016 + A1:2019 + A2:2022 (All clauses except 23, 26, Annex H); EN 60730-2-12:2006 + A11:2008 (All clauses except 23, 26, Annex H); EN IEC 60730-2-12:2019 (All clauses except 23, 26, Annex H); EN IEC 60730-2-14:2019 + A1:2022 + A2:2021 (All clauses except 23, 26, Annex H) [INST] EN IEC 61058-1:2018 (All clauses except 10.4, 14.1, 14.2, 19.2.4, 19.2.5, 23, 25); EN 61058-1-1:2016 (All clauses except 23) 2005-07-07 2023-06-28 IMQ-031/E-CTF2 Issue No: 1
E-CTF-2 EMBRACO SLOVAKIA s.r.o.(Electrical Laboratory) Odorínska Cesta, 2 SK-05201 Spi?ská Nová Ves Slovakia [HOUS] EN 60335 1:2012 + A11:2014 + A13:2017 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 24.5, 30.1); EN 60335-2-34:2013 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 22.101, 24.5, 30.1, Annex AA) 2007-08-01 2021-06-09 IMQ-116/CTF2-B
E-CTF-2 EVOCA S.p.A. (Laboratorio Ricerca e Sviluppo) Via Roma, 24 IT-24030 Valbrembo Bergamo (BG) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15.1, 19.11.4, 21.1, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2, 30, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2 / Annex N, 30, Annex R, Annex T); EN 60335-2-24:2010 + A1:2019 + A2:2019 + A11:2020 (Accepted clauses 7, 10, 11, 19, 22.104, 22.105, 22.112, 22.113, 22.114, 22.115, 24, Annex AA); EN IEC 60335-2-24:2022 + A11:2022 (Accepted clauses 7, 10, 11, 19, 22.104, 22.105, 22.112, 22.113, 22.114, 22.115, 24, Annex AA); EN 60335-2-75:2004 + A1:2005 + A11:2006 + A2:2008 + A12:2010 (All clauses except 15.1.1, 22.47); EN IEC 60335-2-75:2023 + A1:2023 + A2:2023 (All clauses except 15.1.1) 2018-01-10 2026-06-16 IMQ-143/E-CTF2 Issue No: 3
E-CTF-2 FABER S.p.A. (R&D Laboratory) Viale XIII Luglio, 160 IT-60044 Fabriano Fabriano (AN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 11.3 (probe figure 104), 22.110, 22.111, 29.3 (test probe 41 of IEC 61032)); EN 60335-2-31:2014 + A1:2023 + A11:2023 + A2:2023 2006-03-24 2024-01-26 IMQ-093/E-CTF2 Issue No: 3
E-CTF-2 FANTON S.p.A. Viale dell’Industria, 8/10IT-35026 ConselvePadova (PD) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 2005-09-22 2022-10-01 IMQ-044/E-CTF2 Issue No: 1
E-CTF-2 FINDER S.p.A. Via Drubiaglio, 14 IT-10040 Almese Torino (TO) Italy [INST] EN 60669-1:2018 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 15.2, 20, 24.2, 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-2:2006 (All clauses except 15.2, 20, 24.2, 26) [CONT] EN 61810-1:2015 + A1:2020 (All clauses except 13); EN 61810-3:2015; EN 61095:2009 (All clauses except 9.3.3.4.1 item b (Impulse withstand voltage test), 9.3.4); EN 60730-1:2016 + A1:2019 + A2:2022 (Accepted clauses 13, 14, 16, 17, Annex U) 2006-02-21 2023-03-23 IMQ-068/E-CTF2 Issue No: 2
E-CTF-2 ELBA ITALY S.p.A. (Laboratorio Ricerca e Sviluppo) [Former: FISHER & PAYKEL APPLIANCES ITALY S.p.A. (Laboratorio Ricerca e Sviluppo)] Via Fabbian Matteo, 7 IT-31030 Borso del Grappa Treviso (TV) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 19.11.4 (EMP), 22.48, 30, Annex E, Annex F, Annex H, Annex N, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021 + A16:2023 (All clauses except 19.11.4 (EMP), 22.48, 30, Annex E, Annex F, Annex H, Annex N, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-2-6:2015 + A11:2020 + A1:2020 (All clauses except 22.110, 22.111, 29, 30.1, 30.2, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2009-03-31 2024-05-03 IMQ-150/E-CTF2 Issue No: 3
E-CTF-2 FLOS S.p.A. Via Angelo Faini, 2 IT-25073 Bovezzo Brescia (BS) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.13.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 13.3.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 60598-2-23:2021; EN 60598-2-24:2013 2005-09-22 2024-04-10 IMQ-043/E-CTF2 Issue No: 2
E-CTF-3 GEWISS S.p.A. [Cenate Sotto] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 61386-1:2008 (All clauses (only for accessories)); EN 61386-21:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-22:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-23:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-24:2010 (All clauses (only for accessories)); EN 60309-1:1999 + A1:2007 + A2:2012; EN IEC 60309-1:2022; EN 60309-2:1999 + A1:2007 + A2:2012; EN IEC 60309-2:2022; EN 60309-4:2007 + A1:2012; EN IEC 60309-4:2022; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 26); EN 60669-2-2:2006 (All clauses except 26); EN 60669-2-3:2006 (All clauses except 26); EN 60669-2-4:2005; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011; EN 61984:2009 (All clauses except 7.3.14) [POW] EN 60947-1:2007 + A1:2011 + A2:2014; EN IEC 60947-1:2021; EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2017 (All clauses except Annex J); EN 60947-3:2009 + A1:2012 + A2:2015; EN IEC 60947-3:2021; EN 60947-5-1:2017; EN 61439-1:2011; EN IEC 61439-1:2021; EN 61439-2:2011; EN IEC 61439-2:2021; EN 61439-3:2012; EN 61439-4:2013; EN 61439-5:2015; EN 61439-6:2012; EN 62019:1999 + A1:2003 + A11:2005 + A12:2014 [CONT] EN 61095:2009 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61008-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61009-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 62423:2012 + A11:2021 + A12:2022n(All clauses except test sequences H, I, J); EN 63024:2018 (All clauses except test sequence G) [ELVH] EN 62196-1:2014 (All clauses except 26.4); EN 62196-2:2017 (All clauses except 26.4); EN IEC 61851-1:2019 2001-09-12 2023-10-20 IMQ-008/E-CTF3 Issue No: 3
E-CTF-3 GEWISS S.p.A. [Cenate Sopra] Via Provinciale, 61 IT-24060 Cenate Sopra Bergamo (BG) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.4, 4.14.1, 4.20, 4.24 / Annex P, 4.26, 9.2.9); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.14.1, 4.20, 4.24 / Annex P, 4.26); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.1 Annex C); EN 60598-2-24:2013; EN 61347-1:2015 + A1:2021; EN 61347-2-7:2012 + A1:2019 + A2:2022; EN 61347-2-13:2014 + A1:2017; EN IEC 62031:2020 + A11:2021 (All clauses except 21); EN 62262:2002 + A1:2021 - IEC TR 62696:2011 (Accepted test method: Eha: Pendulum Hammer) 2020-07-07 2024-02-06 IMQ-374/E-CTF3 Issue No: 2
E-CTF 2 GEWISS S.p.A. (Laboratorio di Compatibilità Elettromagnetica) [Prod. Cat.: EMC] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [EMC] EN 50491-5-2:2010 (Excluded radiated immunity and emission test); EN 50491-5-3:2010 (Excluded radiated immunity and emission test); EN 50557:2011 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 55014-1:2006 + A1:2009 + A2:2011 (Excluded radiated emission test); EN 55014-1:2017 (Excluded radiated emission test); EN 55014-2:2015 (Excluded radiated immunity test); EN 55015:2013 + A1:2015 (Excluded radiated emission test); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60669-2-5:2016 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 7.3 (excluded radiated emission test and only sub-clause 8.4.1 except 8.4.1.2.3)); EN 60947-2:2006 + A1:2009 + A2:2013 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 60947-2:2017 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 61000-6-1:2007 (Excluded radiated immunity test); EN 61000-6-2:2005 (Excluded radiated immunity test); EN 61000-6-3:2007 + A1:2011 (Excluded radiated emission test); EN 61000-6-4:2007 + A1:2011 (Excluded radiated emission test); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (Accepted clauses 4, 5 (except clause 4 Ref. T 2.5 of Tab. 5)); EN 61547:2009 (Excluded radiated immunity test); EN 62493:2015 (Excluded radiated immunity test); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J) 2017-09-25 2018-12-05 IMQ-145/CTF2-A
E-CTF-2 GEWISS S.p.A. (Laboratorio Prove GW130) Via Emilia Pavese, 53 IT-29015 Castel San Giovanni Piacenza (PC) Italy [INST] EN 61386-1:2008 + A1:2017 (All clauses except 14); EN 61386-21:2004 + A11:2010 (All clauses except 14); EN IEC 61386-22:2021 + A11:2021 (All clauses except 14); EN 61386-22:2004 + A11:2010 (All clauses except 14); EN IEC 61386-22:2021 + A11:2021 (All clauses except 14); EN 61386-23:2004 + A11:2010 (All clauses except 14); EN IEC 61384-23 (All clauses except 14) 2016-04-13 2022-09-15 IMQ-284/E-CTF2 Issue No: 1
E-CTF-3 HAGER ELECTRO SAS Boulevard d'Europe, 132 FR-67210 CEDEX Obernai France [INST] EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-2:2006; EN 60669-2-4:2005 [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses and for EMC only Immunity testing); EN IEC 60947-1:2021 (All clauses and for EMC only Immunity testing); EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses and for EMC only Immunity testing); EN 60947-2:2017 + A1:2020 (All clauses and for EMC only Immunity testing); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses and for EMC only Immunity testing); EN IEC 60947-3:2021 (All clauses and for EMC only Immunity testing); EN 60947-4-1:2010 + A1:2012; EN IEC 60947-4-1:2019; EN 60947-5-1:2004 + A1:2009 (All clauses and for EMC only Immunity testing); EN 60947-5-1:2017 (All clauses and for EMC only Immunity testing) [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses and for EMC only Immunity testing); EN 61008-2-1:1994 + A11:1998 (All clauses and for EMC only Immunity testing); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 + A13:2021 (All clauses and for EMC only Immunity testing); EN 61009-2-1:1994 + A11:1998 (All clauses and for EMC only Immunity testing); EN 62423:2012 + A11:2021 + A12:2022 (All clauses and for EMC only Immunity testing) [CONT] EN 61095:2009 [SAFE] EN 61558-1:2005 + A1:2009 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN IEC 61558-1:2019 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN 61558-2-6:2009 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN 61558-2-8:2010 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X) 2010-04-14 2023-12-21 IMQ-188/E-CTF3 Issue No: 2
E-CTF-1 ICEL S.r.l. (LABORATORIO E SALA PROVE ICEL) Via Carlo Jucker, 16 IT-21053 Castellanza Varese (VA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.9, 5.13, 5.14) 2005-09-30 2024-05-29 IMQ-048/E-CTF1B Issue No: 3
E-CTF-2 IGUZZINI ILLUMINAZIONE S.p.A. (Laboratorio Normativo/Sicurezza) Via Mariano Guzzini, 37 IT-62019 Recanati Macerata (MC) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13.6, 4.20, 4.28, 4.34, 4.35, 9.2.10, 9.2.11, 13.3.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 60598-2-24:2013; EN 62031:2020 + A11:2021 (All clauses except 7, 21.1, Annex A, Annex D); EN 60570:2003 + A1:2018 + A2:2020; EN 62262:2002 + A1:2021 - IEC TR 62696:2011 (Accepted clause test Ehc (vertical hammer), according to IEC 60068-2-75:2014); IEC TR 62778:2014 [EMC] EN IEC 61000-3-2:2019 + A1:2021; EN 61000-3-3:2013 + A1:2019 + A2:2021; EN IEC 55015:2019 + A11:2020 (All clauses except: - No. 7 Method of insertion loss measurement - No. 9 Method of radiated electromagnetic disturbances (semi-anechoic chamber)); EN 61000-4-5:2014 + A1:2017 1992-02-07 2024-04-03 IMQ-011/E-CTF2 Issue No: 2
E-CTF-2 INCO MASSALOMBARDA S.r.l. (LABORATORIO SALA PROVE) Via Marchetti, 88 IT-48024 Massa Lombarda Ravenna (RA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16) 2005-09-30 2023-12-01 IMQ-050/E-CTF2 Issue No: 2
E-CTF-2 ITW Appliance Components S.r.l. (ITW EMEA Laboratory) Via Oltrona, 23 IT-21020 Barasso (VA) Italy [INST] EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004; EN 60998-2-2:2004; EN IEC 61058-1:2018 (Only for mechanical switches - Only for resistive-motor load); EN 61058-1-1:2016 (Only for mechanical switches - Only for resistive-motor load); EN 61058-2-4:2005 (Only for mechanical switches - Only for resistive-motor load) [HOUS] EN 60335-1:2012 + A11:2014 (Accepted clauses 25.15, 28, 30 (except 30.2.4), Annex N) 2018-09-20 2023-12-04 IMQ-343/E-CTF2 Issue No: 2
E-CTF-2 IVELA S.r.l. Via Bruno Buozzi, 15 IT-20060 Liscate Milano (MI) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.9.2, 4.12.5, 4.13.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 5.2.10.1, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 10.3, 11.2.1, 13.3.1, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60570:2003 + A1:2018 + A2:2020 (All clauses except 12.3.1, 14) 2005-09-23 2024-05-22 IMQ-047/E-CTF2 Issue No: 2
E-CTF-2 KEMET ELECTRONICS CORPORATION - KEMET ELECTRONICS ITALIA S.r.l. Via Sagittario, 1/3 IT-40037 Sasso Marconi Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.14, 5.15, 5.16); EN 60252-2:2011 + A1:2013 (All clauses except 5.1.17, 6); EN 60384-14:2013 + A1:2016 (Accepted clauses 4.1, 4.2, 4.3, 4.4, 4.11, 4.12, 4.13, 4.14, 4.15, 4.17, 4.18, 4.20, Annex H, Annex I); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:2014 (Accepted clauses 17, 18, 19); EN 61048:2006 + A1:2016 (Accepted clauses 13, 14, 15, 17, 18); EN 61049:1993 (Accepted clauses 6, 8) 2005-09-30 2023-07-28 IMQ-052/E-CTF2 Issue No: 2
E-CTF-2 LOVATO ELECTRIC S.p.A. (LABORATORIO DI PROVA (LPR)) Via Don Emilio Mazza, 12 IT-24020 Gorle (BG) Italy [CONT] EN 60730-1:2016 + A1:2019 (Accepted clauses 11.3.5, 11.3.6, 11.3.7, 11.3.8, 17) [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.4); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.4); EN 60947-4-1:2018 (All clauses except 9.4); EN 60947-5-1:2016 (All clauses except 8.4) 2017-11-06 2021-09-27 IMQ-311/E-CTF2 Issue No: 0
E-CTF-2 MENEGHETTI S.p.A. Via Generale Cadore, 26 IT-21010 Cardano al Campo (VA) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 22.48, 25.14, 25.15, 26, 28, 30, Annex F, Annex H, Annex R, Annex T, IEC/EN 62233 (EMF); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 22.48, 25.14, 25.15, 26, 28, 30, Annex F, Annex H, Annex R, Annex T, IEC/EN 62233 (EMF); EN 60335 2-6:2015 + A1:2020 + A11:2020 (All clauses except 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN IEC 60335-2-25:2021 + A11:2021 (All clauses except 16, 18, 22.105, 22.106, 22.115, 22.116, 22.119, Annex BB); EN 60335-2-102:2016 (All clauses except 8.101) 2018-09-17 2024-02-12 IMQ-342/E-CTF2 Issue No: 3
E-CTF-2 PALAZZOLI S.p.A. (TEST LABORATORY) Via F. Palazzoli, 31 IT-25128 Brescia (BS) Italy [INST] EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 29, 30); EN IEC 60309-1:2021 (All clauses except 29, 30); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 29,30); EN IEC 60309-2:2021 (All clauses except 29, 30); EN 60309-4:2007 + A1:2012 (All clauses except 29, 30); EN IEC 60309-4:2021 (All clauses except 29, 30); EN 62208:2011 (All clauses except 9.5, 9.12, 9.13) [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted clauses 5, 7.1.2.2, 8.3.3.3, 8.3.3.4 (excluded impulse withstand voltage), 8.3.3.6, 8.3.3.7); EN IEC 60947-1:2021 (Accepted clauses 8.1.2.2, 8.1.12 + Annex C, 9.3.3.3, 9.3.3.4 (excluded impulse withstand voltage), 9.3.3.6, 9.3.3.7); EN 60947-3:2009 + A1:2012 + A2:2015 (Accepted clauses 5, 7.1.2.2 Test Sequence II (8.3.4.1, 8.3.4.2, 8.3.4.3, 8.3.4.4), 8.5.1, 8.5.2); EN IEC 60947-3:2021 (Accepted clauses 8.1.2.2, Test Sequence II (9.3.5.2, 9.3.5.3, 9.3.5.4, 9.3.5.5), 9.5.2, 9.5.3) 2006-03-16 2024-02-16 IMQ-062/E-CTF2 Issue No: 2
E-CTF-2 PERFORMANCE IN LIGHTING S.p.A. Viale del Lavoro, 9/11 IT-37030 Colognola ai Colli Verona (VR) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 10.3.1, 11.2.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 10.3.1, 11.2.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 12.1, 17, 18, 20, 21, Annex D) 2005-04-14 2023-11-09 IMQ-021/E-CTF2 Issue No: 2
E-CTF-2 PIZZATO ELETTRICA S.r.l. (Laboratorio Prove P6) Corso della Ceramica, 56/B IT-36063 Marostica Vicenza (VI) Italy [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.1.2.2, 8.4.1.2.3, 8.4.1.2.6, 8.4.1.2.7, 8.4.2, Annex K - For Annex C (Degrees of protection of enclosed equipment): Applicable clauses 14.2.4, 14.2.5, 14.2.6, 14.2.7, 14.2.8 of EN 60529:1991 + A1:2000 + A2:2013); EN IEC 60947-1:2020 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.1.2.2, 8.4.1.2.3, 8.4.1.2.6, 8.4.1.2.7, 8.4.2 - For Annex C (Degrees of protection of enclosed equipment): Accepted clauses 14.2.4, 14.2.5, 14.2.6, 14.2.7, 14.2.8 of IEC 60529:1989 + A1:1999 + A2:2013 / EN 60529:1991 + A1:2000 + A2:2013; EN 60947-5-1:2004 + A1:2009 (All clauses except 8.3.4); EN 60947-5-1:2017 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.2.1, 8.4.2.2, 8.4.2.5, 8.4.2.6, 8.4.3); EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017 (All clauses except Annex A) 2020-09-02 2024-02-23 IMQ-375/E-CTF2 Issue No: 2
E-CTF-2 RELCO S.r.l. Via delle Azalee, 6/A IT - 20090 Buccinasco (MI) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (Accepted clauses 3, 7, 10.2, 11, 12); EN 60598-2-2:2012 (Accepted clauses 2.6, 2.8, 2.9, 2.13, 2.15); EN 60598-2-3:2003 + A1:2011 (Accepted clauses 3.5, 3.7, 3.8, 3.12, 3.14); EN 60598-2-5:2015 (Accepted clauses 5.5, 5.7, 5.8, 5.12, 5.14); EN 61347-1:2015 + A1:2021 (Accepted clauses 7, 9, 12, 13, 15, 16, 20); EN 61347-2-7:2012 + A1:2019 (All clauses except 8, 9, 11, 14, 15, 16, 17, 18, 19, 20.1, 31, 32, 33, 34.2, 34.5, 35); EN 61347-2-13:2014 + A1:2017 (Accepted clauses 7, 10, 12, 13, 15, 17, 21, Annex J (except J.7, J.8)); EN IEC 62031:2020 + A11:2021 (Accepted clauses 6, 8, 11, 12.2, 14, 15) 2022-03-25 2024-05-22 IMQ-416/E-CTF2 Issue No: 2
E-CTF-2 SCAME PARRE S.p.A. Via Campignano, 9 IT-24020 Parre Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021; EN 61242:1997 + A1:2008 + A2:2016 + A13:2017; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 20 and 21 (for equipment with rated operating voltage > 400V and rated current > 32A)); EN IEC 60309-1:2022 (All clauses except 20 and 21 (for equipment with rated operating voltage > 400 V and rated current > 32 A)); EN 60309-2:1999 + A1:2007 + A2:2012; EN IEC 60309-2:2022; EN 60309-4:2007 + A1:2012; EN IEC 60309-4:2022; EN 61316:1999; EN IEC 61316:2021; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018 (All clauses except 19.3); EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN IEC 60670-1:2021 + A1:2021; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.13); EN IEC 62208:2023 (All clauses except 9.14) [ELVH] EN 62196-1:2014 (All clauses except 22, 23 and 31); EN IEC 62196-1:2022 (All clauses except 22, 23, 31); EN 62196-2:2017; EN IEC 62196-2:2022; EN 62196-3:2014 (All clauses except 26.4); EN IEC 62196-3:2022 (All clauses except 26.4) [POW] EN 61439-1:2011 (All clauses except 10.2.2); EN 61439-1:2021 (All clauses except 10.2.2); EN 61439-4:2013 (All clauses except 10.2.6.3, 10.2.2.101); EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.3.3); EN IEC 60947-1:2021 (All clauses except 9.3); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.3.3, 8.3.5, 8.3.6); EN IEC 60947-3:2021 (All clauses except 9.3.4, 9.3.6, 9.3.7, 9.3.8, 9.3.9) 2005-11-11 2024-03-21 IMQ-069/E-CTF2 Issue No: 3
E-CTF-2 SCHNEIDER ELECTRIC INDUSTRIE ITALIA S.p.A. Via Govoni, 17 IT-40066 Pieve di Cento Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.1, 9.2.2, 9.2.7, 9.2.8, 9.2.9, 10.3.1, 12.5.1e), Annex C Fig. C3); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.5, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 10.3, 12.5 1e), Annex C Fig. C3); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 61347-1:2015 + A1:2021 (All clauses except 14.6, 17, 18.2, 19); EN 61347-2-7:2012 + A1:2019 + A2:2022 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 62262:2002 - IEC TR 62696:2011 2006-02-22 2023-07-28 IMQ-090/E-CTF2 Issue No: 1
E-CTF-2 SIMES S.p.A. Via G. Pastore, 2/4 IT-25040 Nigoline di Corte Franca Brescia (BS) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.20, 4.24.1 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 5.2.10.1, 9.2.10, 9.2.11, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN 60598-2-18:1994 + A1:2012; EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 13.1, 18, 20, 21.1/21.3, Annex A, Annex D); IEC/TR 62778:2014 2010-01-21 2024-04-17 IMQ-236/E-CTF2 Issue No: 2
E-CTF-2 TARGETTI SANKEY S.p.A. (LABORATORIO PROVE TARGETTI) Via Pratese, 164 IT-50145 Firenze Firenze (FI) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.9.2, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3.1, 11.2.1, 12.7.2, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.9.2, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 11.2.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 7, 10, 16, 17, 18, 20, 21, Annex A, Annex D) 1994-01-26 2023-06-22 IMQ-014/E-CTF2 Issue No: 2
E-CTF-1 TECNOINOX S.r.l. (Laboratorio TECNOINOX) Via Torricelli, 1 IT - 33080 Porcia (PN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N); EN 60335-2-48:2003 + A1:2008 + A11:2012 (All clauses ) 2018-10-05 2018-10-05 IMQ-344/CTF1
E-CTF-2 TEKA INDUSTRIAL S.A. (TEKA Laboratory Gas Competence Center) Via Alcide De Gasperi, 20 IT-36060 Pianezze San Lorenzo Vicenza (VI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-2-6:2015 (All clauses except 8, 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2022-06-13 2022-06-13 IMQ-418/E-CTF2 Issue No: 0
E-CTF-2 VIABIZZUNO S.r.l. (Laboratorio Prove Viabizzuno) Via L. Romagnoli, 10 IT-40010 Bentivoglio (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.14, 4.21.4, 4.26, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN IEC 60598-1:2021 + A11:2022 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.14, 4.21.4, 4.26, 4.33, 4.36, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (Accepted clauses: 13.5, 13.6.4, 13.6.5, 13.7, 13.8, 13.9, 13.10, 13.11, 13.12, 13.14, 13.15); EN IEC 62031:2020 + A11:2021 (Accepted clauses: 6.6, 7, 8, 9, 11, 12, 15, 16); EN 61347-1:2015 + A1:2021 (Accepted clauses: 7.2, 10, 12, 14 (excl. 14.7), 16, L.6, L.7); EN 61347-2-11:2001 + A1:2019 (Accepted clauses: 7, 8, 12, 14, 16 (only d.c. supplied miscellaneous electronic circuits used with luminaires up to 48 Vd.c.); EN 61347-2-13:2014 + A1:2017 (Accepted clauses: 7, 8, 12, 14, 15, 17 (only d.c. supplied controlgear up to 48 Vd.c.) 2020-09-25 2023-11-09 IMQ-379/E-CTF2 Issue No: 1
E-CTF-2 VIMAR S.p.A. [Prod. Cat.: INST - PROT] Via IV Novembre, 32 IT-36063 Marostica Vicenza (VI) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 (All clauses except 25.2); EN 60669-1:1999 + A1:2002 + A2:2008 (All clauses except 24.2); EN 60669-1:2018 (All clauses except 24.2); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 24.2, 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 24.2, 26, 103); EN 60669-2-5:2016 (All clauses except 24.2, 26); EN 60670-1:2005 + A1:2013 (All clauses except 19); EN IEC 60670-1:2021 + A11:2021 (All clauses except 19); EN 60670-22:2006 (All clauses except 19); EN 60670-24:2013 (All clauses except 19) 2005-12-05 2024-02-16 IMQ-084/E-CTF2 Issue No: 1
E-CTF-3 CANDY HOOVER GROUP S.r.l. (Cooking & Built-in Lab) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, from 19.11.4.1 to 19.11.4.7); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 22.110, 22.111, 22.135, 22.136, 22.137, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2021-12-01 2024-01-30 IMQ-403/E-CTF3 Issue No: 1
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio MCM (Macchine Caffè Manuali)) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 + A12:2021 + A1:2021 + A2:2021 2022-02-10 2024-06-05 IMQ-408/E-CTF2 Issue No: 2
E-CTF-2 ARTEMIDE S.p.A. (ARTEMIDE LABORATORY) Via Bergamo, 17 IT - 20006 Pregnana Milanese (MI) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.6, 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 12.5.1e Annex C Fig. C3, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13.6, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 12.5.1e Annex C Fig. C3, 13.3.1, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 60598-2-22:2022 (All clauses except 22.13, 22.17.1 Annex C, 22.19); EN IEC 60598-2-23:2021; EN IEC 62031:2020 + A11:2021 (All clauses except 12.1, 18, 21); EN 61347-1:2015 + A1:2021 (Accepted clause 14 except 14.7); EN 61347-2-11:2001 + A1:2019 (Accepted clause 14); EN 61347-2-13:2014 + A1:2017 (Accepted clause 14) 2023-05-10 2023-05-10 IMQ-428/E-CTF2 Issue No: 0
E-CTF-2 ELECTROLUX PROFESSIONAL S.p.A. (Electrolux Professional Laboratory) [452] Viale Treviso, 15 IT-33170 Pordenone (PN) Italy [HOUS]Hot Laboratory: EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN IEC 60335-1:2023 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 22.110, 22.111, 30, 32.101); EN 60335-2-36:2002 + A1:2004 + A2:2008 + A11:2012; EN 60335-2-38:2003 + A1:2008; EN 60335-2-39:2003 + A1:2004 + A2:2008; EN 60335-2-42:2003 + A1:2008 + A11:2012; EN 60335-2-50:2003 + A1:2008; EN 60335-2-64:2000 + A1:2002; EN 60335-2-90:2006 + A1:2010; EN 60335-2-102:2016 (All clauses except 8.101). [HOUS] Refrigeration Laboratory: EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex N, Annex T); EN 60335-2-89:2010 + A1:2016 + A2:2017 (All clauses except 15.102, 22.103, 22.104, 22.106, 22.107, 22.108); EN 60335-2-89:2022 + A11:2022 (All clauses except 15.102, 22.103, 22.104, 22.106, 22.107, 22.108). 2024-02-13 2024-02-13 IMQ-452/E-CTF2 Issue No: 0
E-CTF-2 ZOBELE HOLDING S.p.A. (Electrical Testing Laboratory) Via Fersina, 4 IT - 38123 Trento (TN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 25.14, 27.5); EN 60335-2-101:2002 + A1:2008 + A2:2014 2024-05-06 2024-05-06 IMQ-457/E-CTF2 Issue No: 0
E-CTF-2 VORTICE S.p.A. (Laboratorio Prove R&D) [458] Strada Cerca, 2 - Frazione Zoate I-20067 Tribiano (MI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 19.11.4 (EMP), 22.48); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 19.11.4 (EMP), 22.48, Annex R; Annex T, Annex U); EN 60335-2-30:2009 + A11:2012 + A1:2020 + A12:2020 + A13:2022 + A2:2022 (All clauses except 22.7); EN 60335-2-80:2003 + A1:2004 + A2:2009 (All clauses except 20.101) 2024-05-16 2024-05-16 IMQ-458/E-CTF2 Issue No: 0
E-CTF-2 THERMOWATT S.p.A. (LABORATORIO THERMOWATT ARCEVIA ELETTROMECCANICA) Via San Giovanni Battista, 21 IT-60011 Arcevia (AN) Italy [CONT] EN 60730-1:2011 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26, Annexes C-E-H-J-P-Q-R-U); EN 60730-1:2016 + A1:2019 + A2:2022 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26, Annexes C-E-H-J-P-Q-R-U); EN IEC 60730-2-9:2019 + A1:2019 + A2:2020 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26, Annexes C-E-H-J-P-Q-R-U-DD) 2022-11-22 2024-06-26 IMQ-421/E-CTF2 Issue No: 1
Scheme Given name Family name Location Certification decision Signatory Scope limitation Terminated
ENEC+ Fulvio Giorgi Milano 2014-01-01
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Giorgio Belussi Milano 2017-01-01 2017-01-01
ENEC+ Giorgio Belussi Milano 2014-01-01 2014-01-01
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Mauro Casari Milano 2008-01-01 2008-01-01
ENEC+ Mauro Casari Milano 2014-01-01 2014-01-01
HAR Marco Piazza Milano 2005-01-01 2005-01-01 CABL
ENEC, CCA Marco Piazza Milano 2005-01-01 2005-01-01 LITE, SAFE
CCA/NTR Marco Piazza Milano 2005-01-01 2023-03-01 CABLE, LITE, SAFE
ENEC, CCA Fabrizio Stucchi Milano 2013-01-01 2013-01-01 LITE, SAFE 2016-12-31
CCA/NTR Fabrizio Stucchi Milano 2013-01-01 LITE, SAFE 2016-12-31
ENEC, CCA Massimiliano Rancati Milano 2016-01-01 2016-01-01 LITE, SAFE 2019-12-31
CCA/NTR Massimiliano Rancati Milano 2016-01-01 LITE, SAFE 2019-12-31
ENEC, CCA Augusto Ciciotti Milano 2005-01-01 2005-01-01 INST, PROT, POW, MISC 2017-12-31
CCA/NTR Augusto Ciciotti Milano 2005-01-01 INST, PROT, POW, MISC 2017-12-31
ENEC, CCA Fabio Taormina Milano 2017-01-01 2017-01-01 CONT, ELVH, INDA, INST, MISC, POW, PROT
CCA/NTR Fabio Taormina Milano 2017-01-01 2013-03-01 CONT, ELVH, INDA, INST, MISC, POW, PROT
ENEC, CCA Armando Benvenuti Milano 2008-01-01 2008-01-01 HOUS, TOOL
CCA/NTR Armando Benvenuti Milano 2008-01-01 2023-03-01 HOUS, TOOL
ENEC, CCA Stefano De Mas Milano 2014-01-01 2014-01-01 CAP, HOUS, MED, MEAS 2023-08-31
CCA/NTR Stefano De Mas Milano 2014-01-01 CAP, HOUS, MED, MEAS 2023-08-31
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Fulvio Giorgi Milano 2011-01-01
ENEC, CCA Mauro Agnolet Milano 2019-01-01 2019-01-01 CAP, ITAV, OFF, TRON
CCA/NTR Mauro Agnolet Milano 2019-01-01 2023-03-01 CAP, ITAV, OFF, TRON
ENEC, CCA, CCA/NTR, CCA/EMC Flavio Cimardi Milano 2020-01-01 2023-03-01 CONT, EMC, INST, MEAS, MED
Given name Family name Location Registered date Terminated date
Giorgio Belussi Italy 2021-04-09
Luca Bergamo Italy 2021-04-09
Paolo Brambilla Italy 2021-04-09
Filippo Brivio Italy 2021-04-09
Bruno Brusaferri Brazil 2021-04-09
Andrea Capitanelli Italy 2021-04-09
Giuseppe Cassano Italy 2021-04-09
Fulvio Colombo Italy 2021-04-09
Massimo Di Dionisio Italy 2021-04-09
Diego Ferrari Italy 2021-04-09 2022-09-05
Filippo Fiorentini Italy 2021-04-09
Antonio Forcina Italy 2021-04-09
Stefano Grilli Italy 2021-04-09
Paolo Magnani Italy 2021-04-09
Mario Marchelli Italy 2021-04-09
Roberto Mollo Italy 2021-04-09
Pasquale Pastocchi Italy 2021-04-09
Paolo Raffa Italy 2021-04-09
Livio Righetto Italy 2021-04-09
Giovanni Rodella Italy 2021-04-09 2022-08-24
Davide Sanvito Italy 2021-04-09
Giuseppe Scuderini Italy 2021-04-09 2023-05-01
Marco Tagliaferri Italy 2021-04-09
Claudio Veronese Italy 2021-04-09
Natalino Verzotto Italy 2021-04-09
Raffaele Villa Italy 2021-04-09
Berk Biricik Turkey 2021-04-09
Jorge López Spain 2021-04-09 2023-11-30
Ming (Simeon) Chen China 2021-04-09
Yafeng (Ivan) Cheng China 2021-04-09
TiaoHui (William) Liu China 2021-04-09
Gabriele Panzeri China 2021-04-09
HongYun (Terry) Qiu China 2021-04-09
Aike (Echo) Yang China 2021-04-09 2022-01-01
Mingjun (Stephen) Zhou China 2021-04-09
Anna Wronska Poland 2023-10-17
Riccardo Barbaro China 2021-04-09
David Latorre Diaz Spain 2024-02-09